Pulseless Electrical Activity
Monitor setup
Each channel runs its own lead and its own alarm limits. A limit is breached when the rate leaves that range.
Feel the rhythm
No pulse — nothing to feel
This rhythm generates no cardiac output, so there is no beat under your fingers. You hear the monitor alarm instead.
Rate
Organized, rate varies
Rhythm type
Non-shockable
Category
Cardiac arrest
Recognise it
- Organized electrical activity on the monitor with no palpable pulse
- Any organized rhythm can be PEA — sinus, junctional, idioventricular
- Always a symptom of an underlying cause, never a diagnosis
Treat it — AHA sequence
- 01
CPR immediately
High-quality compressions at 100–120/min, 2 cm–2.4 inches deep, minimal interruptions, with a rhythm check every 2 minutes.
- 02
Epinephrine 1 mg IV/IO every 3–5 min
Give as soon as the IV/IO is available and repeat every 3–5 minutes.
- 03
Find the cause with bedside ultrasound
Point-of-care echo during the rhythm check helps identify tamponade, right heart strain, hypovolemia or a collapsed lung.
- 04
Treat the reversible cause
Fluids and blood for hypovolemia, needle decompression or thoracostomy for tension pneumothorax, pericardiocentesis for tamponade, thrombolytics for suspected PE, sodium bicarbonate for hyperkalemia, naloxone for opioids.
- 05
Do not shock
Defibrillation has no role unless the rhythm degenerates into VF or pulseless VT.
Clinical pearl
In PEA, the algorithm follows the cause. If the rhythm stays organized but pulseless, think volume, pressure or obstruction.
AHA 2020 ACLS — Adult Cardiac Arrest Algorithm