Second-Degree AV Block, Type I
Monitor setup
Each channel runs its own lead and its own alarm limits. A limit is breached when the rate leaves that range.
Feel the rhythm
55 beats a minute
Turn the volume up, or hold the phone so you feel each thump. One double thump is one heartbeat.
Rate
Variable
Rhythm type
Bradycardia
Category
Bradycardia & blocks
Recognise it
- PR interval progressively lengthens until a QRS is dropped
- The dropped beat is followed by a reset (shortest PR)
- Usually an AV nodal block with a narrow QRS
Treat it — AHA sequence
- 01
Monitor first
Asymptomatic Wenckebach in a stable patient is usually observed with continuous cardiac monitoring.
- 02
Stop contributing medications
Review beta-blockers, calcium channel blockers, digoxin and other AV-nodal blockers.
- 03
Atropine 1 mg IV if symptomatic
Repeat every 3–5 minutes to a maximum of 3 mg; the block is typically vagally mediated and responds well.
- 04
Pacing if atropine fails
Transcutaneous pacing, then a dopamine or epinephrine infusion if pacing is unavailable or ineffective.
Clinical pearl
Mobitz I rarely progresses to complete heart block — but in acute inferior MI it can, so keep monitoring.
AHA 2020 ACLS — Adult Bradycardia Algorithm