Rhythm library
BradycardiaBradycardia & blocks · Mobitz I

Second-Degree AV Block, Type I

Bed 03 · Adult
25 mm/s · 10 mm/mV17:48:58
IIECG
55bpm50–120
V1ECG
55bpm50–120
No active alarms

Monitor setup

Each channel runs its own lead and its own alarm limits. A limit is breached when the rate leaves that range.

Channel 1
Channel 2

Feel the rhythm

55 beats a minute

Turn the volume up, or hold the phone so you feel each thump. One double thump is one heartbeat.

Vibration on Android phones, sound everywhereRegular interval

Rate

Variable

Rhythm type

Bradycardia

Category

Bradycardia & blocks

Recognise it

  • PR interval progressively lengthens until a QRS is dropped
  • The dropped beat is followed by a reset (shortest PR)
  • Usually an AV nodal block with a narrow QRS

Treat it — AHA sequence

  1. 01

    Monitor first

    Asymptomatic Wenckebach in a stable patient is usually observed with continuous cardiac monitoring.

  2. 02

    Stop contributing medications

    Review beta-blockers, calcium channel blockers, digoxin and other AV-nodal blockers.

  3. 03

    Atropine 1 mg IV if symptomatic

    Repeat every 3–5 minutes to a maximum of 3 mg; the block is typically vagally mediated and responds well.

  4. 04

    Pacing if atropine fails

    Transcutaneous pacing, then a dopamine or epinephrine infusion if pacing is unavailable or ineffective.

Clinical pearl

Mobitz I rarely progresses to complete heart block — but in acute inferior MI it can, so keep monitoring.

AHA 2020 ACLS — Adult Bradycardia Algorithm

ClinicalGridRhythm lab
AHA 2020 guideline drills

Educational simulation only. Not a substitute for clinical judgment, local protocols or current AHA publications.