Junctional Rhythm
Monitor setup
Each channel runs its own lead and its own alarm limits. A limit is breached when the rate leaves that range.
Feel the rhythm
45 beats a minute
Turn the volume up, or hold the phone so you feel each thump. One double thump is one heartbeat.
Rate
40–60/min
Rhythm type
Bradycardia
Category
Bradycardia & blocks
Recognise it
- Narrow QRS with absent, inverted or retrograde P waves
- Rate 40–60/min (accelerated junctional 60–100)
- An escape rhythm when the sinus node fails or the AV node is suppressed
Treat it — AHA sequence
- 01
Treat the cause, not the rhythm
Common drivers are digoxin toxicity, inferior ischemia, post-cardiac surgery, AV-nodal blockers and increased vagal tone.
- 02
Assess for symptoms
If the patient is perfusing adequately, observe with monitoring and correct the underlying problem.
- 03
Atropine for symptomatic bradycardia
Atropine 1 mg IV every 3–5 minutes to a maximum of 3 mg.
- 04
Pacing or chronotropes if refractory
Transcutaneous pacing, dopamine 5–20 mcg/kg/min or epinephrine 2–10 mcg/min.
Clinical pearl
Junctional rhythm is a rescue mechanism — the AV node is doing its job. Ask what silenced the sinus node.
AHA 2020 ACLS — Adult Bradycardia Algorithm